T: 01664 370465
STRESS
TEST CHAMBERS
Test your specimen for stress limits with quality stress test chambers from Nexia Scientific Ltd. We work with businesses across the UK and Ireland.
SERIES TS AND CS
Our temperature and climatic stress screening test chambers are designed using a modular concept from the standard series. The powerful compressor and high fan capacity allow extremely high temperature change rates of up to 30 K/min with conventional refrigeration technology and up to 70 K/min. with liquid nitrogen. These units will give you the ability to determine the stress limits of your specimen very quickly.
-
Minimum external measurements due to compact method of construction
-
Optimised parameters for highest testing precision
-
Minimum noise level
Standard version of the TS/CS line:
-
Multicolour touch panel / 32 bit controller
-
Service-friendly capacitive humidity measurement system
-
Single-hand operated door handle, lockable
-
Entry port ø 50 mm
-
Shelf, stainless steel
-
Display in plain text
-
Potential free contact for malfunction signal
-
Ethernet interface
CTS user benefits:
-
Extremely high temperature change rates
-
Service-friendly construction
-
Minimum noise level
-
Simple user-friendly operation and programming
-
Low power-consumption
-
Optimised parameters for highest testing precision
-
Complies with current CE and EMC regulation
-
Demineralised water system with water-level gauge
Test space capacity in litres:
5 K/min - 200 / 350 / 600 / 1000 / 1500
10 K/min and 15 K/min - 200 / 350 / 500 / 810 / 900 / 1250
Temperature range:
-40 °C / +180 °C
-70 °C / +180 °C
Temperature change rates:
5 to 30 K/min
Design:
Control: microprocessor control and monitoring system
Test space: stainless steel grade 1.4301
Refrigerants: chloride free, hermetically sealed
Humidity system (only type CS): capacitive measuring
-
Additional entry ports ø 50 mm, 80 mm and 125 mm
-
Additional shelves
-
Panoramic window, multiple glazed, sized 570 x 710 mm
-
Glove box hand-hole in the door
-
Additional pt 100 for temperature measuring on test specimen alternative reversible to controller function
-
Air dryer system
-
Mobile design – wheels
-
Temperature protection for test-specimen
-
Water cooled compressor; external condenser
-
CID software for programming and documentation
-
Variable air speed in the test space
-
RS 232 interface
-
USB port
-
Other chamber sizes and options on request.
Type | Measure | Unit | 5 K/min4 | ||||
---|---|---|---|---|---|---|---|
Series | TS -40/…, CS -40/…
TS -70/…, CS -70/… | TS -40/…, CS -40/…
TS -70/…, CS -70/… | -40/200-5
-70/200-5 | -40/350-5
-70/350-5 | -40/600-5
-70/600-5 | -40/1000-5
-70/1000-5 | -40/1500-5
-70/1500-5 |
Test Space | liters | 200 | 350 | 600 | 1000 | 1500 | |
Test Space Dimensions | height | mm, appr. | 750 | 750 | 850 | 900 | 900 |
width | mm, appr. | 650 | 650 | 850 | 1000 | 1000 | |
depth | mm, appr. | 400 | 720 | 830 | 1100 | 1600 | |
Overall Dimensions | height | mm, appr. | 1800 | 1800 | 1900 | 1950 | 1950 |
width | mm, appr. | 920 | 920 | 1120 | 1270 | 1270 | |
depth | mm, appr. | 1345 | 1665 | 1875 | 2245 | 2745 | |
Temperature Tests | |||||||
Temperature Range | TS -40/…, CS -40/… | °C | -40/+180 | -40/+180 | -40/+180 | -40/+180 | -40/+180 |
TS -70/…, CS -70/… | °C | -70/+180 | -70/+180 | -70/+180 | -70/+180 | -70/+180 | |
Temp. Change Rate
Cooling | TS -40/…, CS -40/… | K/min | 5,0 | 5,0 | 7,0 | 5,0 | 5,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 5,0 | 5,0 | 7,0 | 5,0 | 5,0 |
Temp. Change Rate
Heating | TS -40/…, CS -40/… | K/min | 8,0 | 8,0 | 6,0 | 6,0 | 5,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 8,0 | 8,0 | 6,0 | 6,0 | 5,0 |
max. Thermal Load
at +20°C | TS -40/…, CS -40/… | W | 3500 | 3500 | 4500 | 5000 | 6000 |
TS -70/…, CS -70/… | W | 3500 | 3500 | 5000 | 5500 | 5000 | |
Temperature Fluctuation | K | ≤± 0,3 temporally | ≤±0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | v 0,3 temporally | |
Climatic Tests | |||||||
Temperature Range | CS -40/…, CS -70/… | °C | +10 to +95 | +10 to +95 | +10 to +95 | +10 to +95 | +10 to +95 |
Humidity Range | CS -40/…, CS -70/… | % RH | 10 to 98 | 10 to 98 | 10 to 98 | 10 to 98 | 10 to 98 |
Dew Point Range I | CS -40/…, CS -70/… | °C | +7 to +94 | +7 to +94 | +7 to +94 | +7 to +94 | +7 to +94 |
Dew Point Range II | CS -40/…, CS -70/… | °C | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 |
Humidity Fluctuation I | CS -40/…, CS -70/… | % RH | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 |
Humidity Fluctuation II | CS -40/…, CS -70/… | % RH | ≤± 3 | ≤± 3 | ≤± 3 | ≤± 3 | ≤± 3 |
Temperature Fluctuation | CS -40/…, CS -70/… | K | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤±0,3 | ≤± 0,3 |
Nominal Voltage | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | ||
Nominal Power | TS -40/… | kW, appr. | 9,3 | 9,3 | 9,2 | 13,3 | 13,2 |
CS -40/… | kW, appr. | 10,4 | 10,4 | 12,1 | 13,2 | 13,2 | |
TS -70/… | kW, appr. | 10,9 | 10,9 | 14,2 | 16,4 | 16,4 | |
CS -70/… | kW, appr. | 12,0 | 12,0 | 14,2 | 16,4 | 16,4 | |
Condenser | air-cooled | air-cooled | water-cooled | water-cooled | water-cooled | ||
Weight | TS -40/…, CS -40/… | kg, appr. | 500 | 600 | 700 | 850 | 1000 |
TS -40/…, CS -40/… | kg, appr. | 550 | 650 | 750 | 900 | 1100 | |
Noise level | dB(A) | < 58 | < 58 | < 62 | < 62 | < 62 |
Type | Measure | Unit | 10 K/min4 | ||||
---|---|---|---|---|---|---|---|
Series | TS -40/…, CS -40/…
TS -70/…, CS -70/… | TS -40/…, CS -40/…
TS -70/…, CS -70/… | -40/200-10
-70/200-10 | -40/350-10
-70/350-10 | -40/500-10
-70/500-10 | -40/900-10
-70/900-10 | -40/1250-10
-70/1250-10 |
Test Space | liters | 200 | 350 | 500 | 900 | 1250 | |
Test Space Dimensions | height | mm, appr. | 750 | 750 | 820 | 870 | 870 |
width | mm, appr. | 650 | 650 | 850 | 1000 | 1000 | |
depth | mm, appr. | 400 | 720 | 725 | 1000 | 1400 | |
Overall Dimensions | height | mm, appr. | 1800 | 1800 | 2170 | 2230 | 2230 |
width | mm, appr. | 920 | 920 | 1120 | 1270 | 1270 | |
depth | mm, appr. | 1345 | 1665 | 2375 | 2645 | 3145 | |
Temperature Tests | |||||||
Temperature Range | TS -40/…, CS -40/… | °C | -40/+180 | -40/+180 | -40/+180 | -40/+180 | -40/+180 |
TS -70/…, CS -70/… | °C | -70/+180 | -70/+180 | -70/+180 | -70/+180 | -70/+180 | |
Temp. Change Rate
Cooling | TS -40/…, CS -40/… | K/min | 10,0 | 10,0 | 10,0 | 10,0 | 10,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 11,0 | 10,0 | 10,0 | 10,0 | 10,0 |
Temp. Change Rate
Heating | TS -40/…, CS -40/… | K/min | 12,0 | 10,0 | 10,0 | 10,0 | 10,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 12,0 | 10,0 | 10,0 | 10,0 | 10,0 |
max. Thermal Load
at +20°C | TS -40/…, CS -40/… | W | 5000 | 5000 | 7000 | 8000 | 8000 |
TS -70/…, CS -70/… | W | 4000 | 5000 | 5500 | 8000 | 8000 | |
Temperature Fluctuation | K | ≤± 0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | |
Climatic Tests | |||||||
Temperature Range | CS -40/…, CS -70/… | °C | +10 to +95 | +10 to +95 | +10 to +95 | +10 to +95 | +10 to +95 |
Humidity Range | CS -40/…, CS -70/… | % RH | 10 to 98 | 10 to 98 | 10 to 98 | 10 to 98 | 10 to 98 |
Dew Point Range I | CS -40/…, CS -70/… | °C | +7 to +94 | +7 to +94 | +7 to +94 | +7 to +94 | +7 to +94 |
Dew Point Range II | CS -40/…, CS -70/… | °C | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 |
Humidity Fluctuation I | CS -40/…, CS -70/… | % RH | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 |
Humidity Fluctuation II | CS -40/…, CS -70/… | % RH | ≤± 3 | ≤± 3 | ≤± 3 | ≤± 3 | ≤± 3 |
Temperature Fluctuation | CS -40/…, CS -70/… | K | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 |
Nominal Voltage | Nominal Voltage | Nominal Voltage | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz |
Nominal Power | TS -40/… | kW, appr. | 13,4 | 13,4 | 17,5 | 23,0 | 32,0 |
CS -40/… | kW, appr. | 13,4 | 13,4 | 18,6 | 24,1 | 33,0 | |
TS -70/… | kW, appr. | 16,6 | 16,6 | 20,3 | 26,0 | 37,0 | |
CS -70/… | kW, appr. | 16,6 | 16,6 | 20,3 | 26,0 | 35,8 | |
Condenser | water-cooled | water-cooled | water-cooled | water-cooled | water-cooled | ||
Weight | TS -40/…, CS -40/… | kg, appr. | 600 | 700 | 800 | 1000 | 1150 |
TS -40/…, CS -40/… | kg, appr. | 650 | 750 | 900 | 1100 | 1300 | |
Noise level | dB(A) | < 58 | < 58 | < 68 | < 68 | < 73 |
Type | Measure | Unit | 15 K/min4 | |||
---|---|---|---|---|---|---|
Series | TS -40/…, CS -40/…
TS -70/…, CS -70/… | TS -40/…, CS -40/…
TS -70/…, CS -70/… | -40/280-15
-70/280-15 | -40/500-15
-70/500-15 | -40/810-15
-70/810-15 | -40/1250-5
-70/1250-15 |
Test Space | liters | 280 | 500 | 810 | 1250 | |
Test Space Dimensions | height | mm, appr. | 720 | 820 | 870 | 870 |
width | mm, appr. | 650 | 850 | 1000 | 1000 | |
depth | mm, appr. | 615 | 730 | 900 | 1400 | |
Overall Dimensions | height | mm, appr. | 2080 | 2170 | 2230 | 2230 |
width | mm, appr. | 920 | 1120 | 1270 | 1270 | |
depth | mm, appr. | 2165 | 2375 | 2645 | 3145 | |
Temperature Tests | ||||||
Temperature Range | TS -40/…, CS -40/… | °C | -40/+180 | -40/+180 | -40/+180 | -40/+180 |
TS -70/…, CS -70/… | °C | -70/+180 | -70/+180 | -70/+180 | -70/+180 | |
Temp. Change Rate
Cooling | TS -40/…, CS -40/… | K/min | 15,0 | 15,0 | 15,0 | 15,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 15,0 | 15,0 | 15,0 | 15,0 |
Temp. Change Rate
Heating | TS -40/…, CS -40/… | K/min | 15,0 | 15,0 | 15,0 | 15,0 |
acc. IEC 60068-3-5 | TS -70/…, CS -70/… | K/min | 15,0 | 15,0 | 15,0 | 15,0 |
max. Thermal Load
at +20°C | TS -40/…, CS -40/… | W | 5000 | 8000 | 8000 | 8000 |
TS -70/…, CS -70/… | W | 5000 | 8000 | 8000 | 8000 | |
Temperature Fluctuation | K | ≤± 0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | ≤± 0,3 temporally | |
Climatic Tests | ||||||
Temperature Range | CS -40/…, CS -70/… | °C | +10 to +95 | +10 to +95 | +10 to +95 | +10 to +95 |
Humidity Range | CS -40/…, CS -70/… | % RH | 10 to 98 | 10 to 98 | 10 to 98 | 10 to 98 |
Dew Point Range I | CS -40/…, CS -70/… | °C | +7 to +94 | +7 to +94 | +7 to +94 | +7 to +94 |
Dew Point Range II | CS -40/…, CS -70/… | °C | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 |
Humidity Fluctuation I | CS -40/…, CS -70/… | % RH | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 | ≤± 1,5 |
Humidity Fluctuation II | CS -40/…, CS -70/… | % RH | ≤± 3 | ≤± 3 | ≤± 3 | ≤± 3 |
Temperature Fluctuation | CS -40/…, CS -70/… | K | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 |
Nominal Voltage | Nominal Voltage | Nominal Voltage | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz |
Nominal Power | TS -40/… | kW, appr. | 17,6 | 24,0 | 32,0 | 42,5 |
CS -40/… | kW, appr. | 18,7 | 24,0 | 33,0 | 43,6 | |
TS -70/… | kW, appr. | 21,2 | 27,4 | 37,1 | 46,8 | |
CS -70/… | kW, appr. | 21,2 | 27,4 | 35,8 | 46,8 | |
Condenser | water-cooled | water-cooled | water-cooled | water-cooled | ||
Weight | TS -40/…, CS -40/… | kg, appr. | 800 | 900 | 1100 | 1350 |
TS -40/…, CS -40/… | kg, appr. | 900 | 1000 | 1200 | 1500 | |
Noise level | dB(A) | < 68 | < 68 | < 73 | < 75 |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
We reserve the right to make alterations due to technical development.